"Exadata V2... Oracle grid consolidation in a box"
Link:
http://blogs.sun.com/glennf/entry/exadata_v2_oracle_grid_consolidation
Link:
http://blogs.sun.com/glennf/entry/exadata_v2_oracle_grid_consolidation
Oracle and Sun's Flash Cache technology combines New features in Oracle with the Sun Storage F5100 to improve database performance. In Oracle databases, the System Global Area (SGA) is a group of shared memory areas that are dedicated to an Oracle “instance” (Oracle processes in execution sharing a database) . All Oracle processes use the SGA to hold information. The SGA is used to store incoming data (data and index buffers) and internal control information that is needed by the database. The size of the SGA is limited by the size of the available physical memory.
This benchmark tested and measured the performance of a new Oracle Database 11g (Release2) feature, which allows to extend the SGA size and caching beyond physical memory, to a large flash memory storage device as the Sun Storage F5100 flash array.
One particular benchmark test demonstrated a dramatic performance improvement (almost 5x) using the Oracle Extended SGA feature on flash storage by reaching SGA sizes in the hundreds of GB range, at a more reasonable cost than equivalently sized RAM and with much faster access times than disk I/O.
The workload consisted in a high volume of SQL select transactions accessing a very large table in a typical business oriented OLTP database. To obtain a baseline, throughput and response times were measured applying the workload against a traditional storage configuration and constrained by disk I/O demand (DB working set of about 3x the size of the data cache in the SGA). The workload was then executed with an added Sun Storage F5100 Flash Array configured to contain an Extended SGA of incremental size.
The tests have shown scaling throughput along with increasing Flash Cache size.
| F5100 Extended SGA Size (GB) | Query Txns / Min | Avg Response Time (Secs) | Speedup Ratio |
|---|---|---|---|
| No | 76338 | 0.118 | N/A |
| 25 | 169396 | 0.053 | 2.2 |
| 50 | 224318 | 0.037 | 2.9 |
| 75 | 300568 | 0.031 | 3.9 |
| 100 | 357086 | 0.025 | 4.6 |


Server Configuration:
Storage Configuration:
Software Configuration:
The workload consisted in a high volume of SQL select transactions accessing a very large table in a typical business oriented OLTP database.
The database consisted of various tables: Products, Customers, Orders, Warehouse Inventory (Stock) data, etc. and the Stock table alone was 3x the size of the db cache size.
To obtain a baseline, throughput and response times were measured applying the workload against a traditional storage configuration and constrained by disk I/O demand. The workload was then executed with an added Sun Storage F5100 Flash Array configured to contain an Extended SGA of incremental size.
During all tests, the in memory SGA data cache was limited to 25 GB .
The Extended SGA was allocated on a “raw' Solaris Volume created with the Solaris Volume Manager (SVM) on a set of devices (Flash Modules) residing on the Sun Storage F5100 flash array.
In order to verify the performance improvement brought by extended SGA, the feature had to be tested with a large enough database size and with a workload requiring significant disk I/O activity to access the data. For that purpose, the size of the database needed to be a multiple of the physical memory size, avoiding the case in which the accessed data could be entirely or almost entirely cached in physical memory.
The above represents a typical “use case” in which the Flash Cache Extension is able to show remarkable performance advantages.
If the DB dataset is already entirely cached, or the DB I/O demand is not significant or the application is already saturating the CPU for non database related processing, or large data caching is not productive (DSS type Queries), the Extended SGA may not improve performance.
It is also relevant to know that additional memory structures needed to manage the Extended SGA are allocated in the “in memory” SGA, therefore reducing its data caching capacity.
Increasing the Extended Cache beyond a specific threshold, dependent on various factors, may reduce the benefit of widening the Flash SGA and actually reduce the overall throughput.
This new cache is somewhat similar architecturally to the L2ARC on ZFS. Once written, flash cache buffers are read-only, and updates are only done into main memory SGA buffers. This feature is expected to primarily benefit read-only and read-mostly workloads.
A typical sizing of database flash cache is 2x to 10x the size of SGA memory buffers. Note that header information is stored in the SGA for each flash cache buffer (100 bytes per buffer in exclusive mode, 200 bytes per buffer in RAC mode), so the number of available SGA buffers is reduced as the flash cache size increases, and the SGA size should be increased accordingly.
Two new init.ora parameters have been introduced, illustrated below:
Results as of October 10, 2009 from Sun Microsystems.