Configuring vSwitch following a S10U4 (08/07) upgrade
In order to enable networking between the domains and the service domain, the LDoms 1.0 Admin guide (pg 42) recommends users to unplumb the physical adapter; and plumb the vSwitch instead. In order for this to function correctly, the LDoms vSwitch will need to be assigned the same MAC address as that of the physical adapter. This workaround is only necessary when the vSwitch is plumbed as a network device, and enable it to receive packets from the external network. A patch to address this issue is in the works and will be released soon.
The issue is also documented in the LDoms 1.0.1 release notes.

I am using Sol10U4, and I find that even if I plumb the vsw0 as the network device, I still need to snoop the underlying bge0 in order for the vsw0 to relay packets from the physical network to the vnet* in the guest ldom.
Is this related? Or something different?
Posted by Jeff Chan on September 27, 2007 at 07:17 PM EDT #
This the same problem. By snooping the underlying adapter, you are forcing the adapter to switch into promiscuous mode. That causes it to pick up all packets including the ones destined for the vSwitch.
-Narayan
Posted by Narayan Venkat on September 27, 2007 at 10:31 PM EDT #
There is another interesing issue, I think, in connection with your topic.
I've got T2000 with 4 ethernet ports. There are 2 domains - primary and logical. I want to attach one of the ethernet ports directly to logical domain, e100g2 exactly.
e100g0 MAC: 0:14:4f:95:1e:42
so I've created
Vsw: primary-vsw1 [num_clients=1]
mac-addr=0:14:4f:95:1e:42
net-dev=e1000g2
mode=prog,promisc
in the primary domain
and attached this service:
Vnet: sunrise-network1
mac-addr=0:14:4f:fa:a7:36
service: primary-vsw1 @ primary
When I reboot primary domain (together with logical, of course),
everything is ok - domains come up and I can ping logical domain
from external physical network
When I reboot logical domain, after it comes up all the pings and
network connections to it stop working - I cannot access logical domain from ext. network anymore. The only way to solve this problem via rebooting primary domain.
Solaris 10 11/06 patched with 118833-36, 124921-02, 125382-01
Any advice ?
Tnanks.
Posted by sol on September 28, 2007 at 06:05 AM EDT #
The fix for this bug (6530331) is in available in 127111-05, once you have that patch installed there is no requirement for the vSwitch to be assigned the same MAC address as that of the physical adapter in order for guest networking to function correctly.
Posted by Liam Merwick on January 09, 2008 at 06:50 AM EST #
Posted by Liam Merwick's Weblog on January 09, 2008 at 07:37 AM EST #